{"product_id":"ffu-hepa-h14-filter-laminar-flow-hood-updated-fanfilter-unit-include-hepa-filter-100-iso-class-5-cleanroom-laboratory-cleanroom-mushroom-room-laminar-air-flow-hood22-6x22-6110v","title":"FFU HEPA H14-Filter Laminar Flow Hood Updated FanFilter Unit（Include HEPA Filter）100\/ISO Class 5 Cleanroom\/Laboratory\/Cleanroom\/Mushroom Room, Laminar Air Flow Hood(22.6\"x22.6\"110V)","description":"\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e generic\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e \u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFFU HEPA H14 filter laminar flow hood: FFU HEPA H14 filter laminar flow hood has CE and ISO certification. The HEPA H14 filtered laminar flow hood ensures that work surfaces are constantly filled with air in a laminar flow manner, and the updated fan filter unit captures 99.995 % of particles larger and smaller than 0.3 microns in diameter, with filtration efficiency meeting 100\/IS0 Level 5 cleanliness\u003c\/li\u003e\n\u003cli\u003eFFU HEPA H14 filter laminar flow hood product material: FFU HEPA H14 filter laminar flow hood is made of galvanized frame, aluminum fan blades, pure copper motor and thickened metal casing, using a safety lock to secure the fan filter Unit work is more durable, safe and efficient\u003c\/li\u003e\n\u003cli\u003eFFUHEPA H14 filter laminar flow hood parameters: 22.6”x22.6”x8.6”, the filtered air flow speed can be set to three speeds, the filtered air flow is 0.45 m\/s (±20 %), the air volume is 600-700 m3\/H (depending on the working environment)\u003c\/li\u003e\n\u003cli\u003eSecondary filtration: 1. A pre-filter is added to the air inlet for the first filtration, 2. A high-efficiency filter is used for the second filtration. The FFUHEPA H14 laminar flow hood has one more filtration process than ordinary equipment, and has a higher degree of cleanliness\u003c\/li\u003e\n\u003cli\u003eScope of Application: The fan filter laminar flow hood supports 110V American plug and can be used in dust-free clean rooms, laboratories, tissue culture seedlings, laminating machines (mobile phone film), laboratories for mobile phone LCD display repair, etc.In some scenarios, it can also be used with our clean shed brackets(ASIN:B0GTYB6N61)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e B0C772TQBJ\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e B0C772TQBJ\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetails:\u003c\/b\u003e FFU HEPA filter laminar flow hood updated fan filter unit, used in dust-free clean room, laboratory, tissue culture seedlings, laminating machine (mobile phone film), used for mobile phone LCD repair laboratory etc.\u003cbr\u003e\n\u003cbr\u003e\nProduct parameters:\u003cbr\u003e\nSize: 22.6*22.6*8.6 inches\u003cbr\u003e\nCabinet material: galvanized plate\u003cbr\u003e\nWheel blade material: aluminum blade\u003cbr\u003e\nFiltration efficiency: 100\/ISO level 5\u003cbr\u003e\nWind speed: 0.45m\/s±20%\u003cbr\u003e\nAir volume: 600-700m3\/h (depending on the working environment)\u003cbr\u003e\nCleanliness: Class 100 (US Federal Standard 209E)\u003cbr\u003e\nNoise: Low speed 41-51. Medium speed 52-59 High speed 59-65\u003cbr\u003e\nVibration value: ≤0.45m\/s2\u003cbr\u003e\nVoltage: AC110V, 60HZ, single phase\u003cbr\u003e\nPower: 200W\u003cbr\u003e\nSpeed regulation mode: three gear speed regulation\u003cbr\u003e\nWiring method: American standard three plug\u003cbr\u003e\n\u003cbr\u003e\nMaintenance\u003cbr\u003e\n1. Do not open and close the filter repeatedly.\u003cbr\u003e\n2. Do not operate the machine with wet hands, otherwise there is a danger of electric shock.\u003cbr\u003e\n3. Do not block the intake valve with any other objects. The fan filter laminar flow hood needs to be kept away from heaters or other heat sources.\u003cbr\u003e\n4. Wipe the laminar air supply unit frequently to keep it clean.\u003cbr\u003e\n5. The fan filter laminar flow hood should be replaced regularly (per cycle every 8-12 months): After replacing the high-efficiency filter, the laminar air supply should be re-tested The technical parameters of the unit can only continue to work after meeting the requirements.\u003cbr\u003e\nDetection\u003cbr\u003e\nIt is recommended to use a particle counter regularly to detect dust particles in the working area of the fan filter laminar flow hood in accordance with the US federal standard The number (cleanliness) and whether the filter is leaking.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eEAN:\u003c\/b\u003e 0797085883115\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePackage Dimensions:\u003c\/b\u003e 26.3 x 25.7 x 15.5 inches\u003c\/p\u003e","brand":"generic","offers":[{"title":"Default Title","offer_id":47616783745214,"sku":"B0C772TQBJ","price":559.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/9893\/6766\/files\/81EASxZs2VL.jpg?v=1780999727","url":"https:\/\/superbuy08.store\/products\/ffu-hepa-h14-filter-laminar-flow-hood-updated-fanfilter-unit-include-hepa-filter-100-iso-class-5-cleanroom-laboratory-cleanroom-mushroom-room-laminar-air-flow-hood22-6x22-6110v","provider":"Super Buy08","version":"1.0","type":"link"}