{"product_id":"hioki-cm4375-50-true-rms-1000-a-ac-dc-clamp-meter","title":"Hioki CM4375-50 - True RMS 1000 A AC\/DC Clamp Meter","description":"\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e Hioki\u003c\/p\u003e\u003cp\u003e\u003cb\u003eColor:\u003c\/b\u003e blue\u003c\/p\u003e\u003cp\u003e\u003cb\u003emodel number:\u003c\/b\u003e CM4375-50\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e CM4375-50\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDetails:\u003c\/b\u003e Can clamp cables below 1.3 inches (34 mm) in diameter. New slim jaw with a new design that fits easily between narrow wiring\u003cbr\u003e\nCompatible with measurements in high temperature environments and freezing temperatures. Operating temperature range: -4°F to 145°F (-25°C to 65°C).\u003cbr\u003e\nTrueRMS (true effective value format) ideal for measuring in noise environments such as around inverter equipment\u003cbr\u003e\nCompatible with CAT IV 600 V, CAT III 1000 V regulated by safety standards.\u003cbr\u003e\n・Displays peak values (wave height) and effective values at the same time.\u003cbr\u003e\nCompatible with the \"GENNECT Cross\" app to manage measured data on your smartphone or tablet. *Wireless adapter Z3210 (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n[Measurement Items]\u003cbr\u003e\nAC current ○, DC current ○, AC + DC current ○, AC voltage ○, DC voltage ○, AC + DC voltage ○,\u003cbr\u003e\nAC power, DC power, resistance, temperature, capacitance, frequency, conductivity check, diode check ○\u003cbr\u003e\n\u003cbr\u003e\n- AC current (range) 1000 A, (accuracy regulation range) 1.0 A to 99.9 A, (representative accuracy) ±1.3% rdg ±0.3 A\u003cbr\u003e\n- DC current (range) 1000 A, (accuracy regulation range) ±1.0 A to ±99.9 A, (representative accuracy) ±1.3% rdg ±0.3 A\u003cbr\u003e\n- AC + DC current (range) 1000 A, (accuracy regulation range) 1.00 A to 99.9 A, (representative accuracy) ±1.3% rdg ±1.3 A\u003cbr\u003e\n- AC voltage (range) 6.000 V\/60.00 V\/600.0 V\/1000 V, (accuracy regulation range) 0.000 V-1000 V, (representative accuracy) ±0.9% rdg ±0.003 V\u003cbr\u003e\n- DC voltage (range) 600.0 mV\/6.000 V\/60.00 V\/600.0 V\/1000 V, (accuracy regulation range) 0.0 mV-±1000 V, (representative accuracy) ±0.5% rdg ±0.5 mV\u003cbr\u003e\n- DC voltage P2000 (sold separately) when using (range) 600.0 V\/2000 V, (accuracy regulation range) 80.0 V to ±2000 V, (representative accuracy) ±1.0% rdg ±0.3 V\u003cbr\u003e\n- AC + DC Voltage 6.000 V\/60.00 V\/600.0 V\/1000 V, (Precision Regulation Range) 0.000 V-1000 V, (Accuracy) ±1.0% rdg ±0.013 V\u003cbr\u003e\n- DC Power (Precision Regulation Range) 0.000 kVA to ±1000 kVA, (Accuracy) ±2.0% rdg ±0.020 kVA\u003cbr\u003e\n- DC Power P2000 (sold separately) when using (accuracy regulation range) 0 kVA to ±2000 kVA, (representative accuracy) ±3.0% rdg ±20 kVA\u003cbr\u003e\n- Resistance (range) 600.0 Ω\/6.000 kΩ\/60.00 kΩ\/600.0 kΩ\/6.000 MΩ, (accuracy regulation range) 0.0 Ω-6.00 MΩ, (representative accuracy) ±0.7% rdg ±0.5 Ω\u003cbr\u003e\n- Temperature (Regulation Range of Accuracy) -40.0°C to 400.0°C, (Accuracy) ±0.5% rdg ±3.0°C\u003cbr\u003e\n- Capacitance (range) 1.000 µF\/10.00 µF\/100.0 µF\/1000 µF, (accuracy regulation range) 0.00 µF to 1100 µF, (representative accuracy) ±1.9% rdg ±0.005 µF\u003cbr\u003e\n- Frequency (Range) 9.99 Hz\/99.99 Hz\/99.9 Hz, (Accuracy Regulation Range) 1.000 Hz to 99.9 Hz, (Accuracy) ±0.1% rdg ±0.003 Hz\u003cbr\u003e\n\u003cbr\u003e\n[Installation Features]\u003cbr\u003e\nAutomatic AC current detection (current\/voltage) ○, maximum \/ minimum \/ average value of measured values (effective value) ○, display the maximum \/ minimum value of wave height (PEAK value) ○, effective value of incoming current ○,\u003cbr\u003e\nBacklight ○, Auto Power Save, Automatic Range Switch, Hold Display Value (Automatic*\/ Manual) ○ *When the measurement value is stable, it will automatically hold the display value.\u003cbr\u003e\n\u003cbr\u003e\nPower Supply:\u003cbr\u003e\n2 AAA alkaline batteries (LR03) or 2 NiMH batteries (HR03)\u003cbr\u003e\n\u003cbr\u003e\nContinuous Usage Time:\u003cbr\u003e\nApproximately 40 hours (when Z3210 is not installed), about 20 hours (with Z3210 equipped and wireless communication). *When using 2 AAA alkaline batteries (LR03).\u003cbr\u003e\n\u003cbr\u003e\n[External Dimensions \/ Weight]\u003cbr\u003e\nApprox. 2.5 x 9.5 x 1.4 inches (65 x 242 x 35 mm), approx. 12.8 oz (350 g) (including batteries).\u003cbr\u003e\n\u003cbr\u003e\nAccessories:\u003cbr\u003e\nL9300 Test Lead, C0203 Portable Case, 2 AAA Alkaline Batteries (LR03) x 2, Instruction Manual (English language not guaranteed)\u003cbr\u003e\n\u003cbr\u003e\nCountry of Origin:\u003cbr\u003e\nJapan\u003c\/p\u003e\u003cp\u003e\u003cb\u003eEAN:\u003c\/b\u003e 4536036013562\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePackage Dimensions:\u003c\/b\u003e 11.0 x 5.7 x 2.8 inches\u003c\/p\u003e","brand":"Hioki","offers":[{"title":"Default Title","offer_id":47634633294014,"sku":"B09ND7LZT9","price":808.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/9893\/6766\/files\/81iPi4u806L.jpg?v=1781513853","url":"https:\/\/superbuy08.store\/products\/hioki-cm4375-50-true-rms-1000-a-ac-dc-clamp-meter","provider":"Super Buy08","version":"1.0","type":"link"}